FERMENTATION / LAB

Sterilizing with a pressure cooker

The home fermenter’s autoclave

What it is for

At about 1 bar above atmospheric pressure (2 atm absolute) a pressure cooker reaches 121 °C, the temperature of a lab autoclave: the only home method that inactivates the toughest bacterial spores. Many home cookers stop lower, so check yours.

When you need it

Agar plates, liquid media, home-lab equipment, low-acid preserves (botulism risk).

Precision
121 °C (about 1 bar above atmospheric) for 15–20 min = a 12-log reduction of C. botulinum spores. The safety standard used worldwide.

What you need

  • Pressure cookerCapacity 6–12 L, working pressure up to about 1 bar above atmospheric (121 °C)
  • Distilled water (500–1000 ml in the bottom)

How to do it

  1. Load it properly500–1000 ml of water in the bottom. Items on a rack, never sitting in the water. Leave room for the steam to circulate.Careful. Never more than two-thirds full.
  2. Bring it up to full pressureClose it and heat on high until the valve hisses: that is the working pressure. 121 °C takes about 1 bar above atmospheric, so check how high your cooker goes.
  3. Hold 15–20 minutes at full pressureTurn the heat down to keep the pressure steady: 15 minutes for small tools, 20 for larger volumes.Why. Time counts from stable pressure. C. botulinum spores: a reduction of more than 12 logs at 121 °C × 15 min.
  4. Let it cool on its ownTurn off the heat and let it cool. Open it only when the gauge reads 0 (30–60 minutes).Careful. NEVER open it under pressure: a blast of steam above 100 °C.

Common mistakes

Opening it before the pressure is gone

What happens
A blast of steam, serious burns
How to avoid it
Wait for the gauge to read zero; never force the lid

Timing from when you turn on the heat instead of from full pressure

What happens
Incomplete sterilization: spores survive
How to avoid it
Start timing ONLY once the valve hisses steadily

Safety

  • Heat-proof gloves to handle it after use
  • Check the gasket and safety valve regularly

The why, in short

Water boils at 100 °C at 1 atm. With about 1 bar more (2 atm absolute) it boils at 121 °C, the temperature that inactivates endospores (Bacillus, Clostridium). It is the autoclave principle.

Written by the Fermentation Lab team, the same text as the app's Library. Found a mistake? Write to us: fermentationlabapp@gmail.com